Digital pulse counter CD6-3/220V

N=(1 - 999999), Us=220Vac, Output 4A/220V, 95x49x113mm

Price 79.04 EUR no VAT

The CD6-3/220V digital pulse counter is a microprocessor device with a 6-digit display. It counts up to 999999 and has one output relay. An additional feature of the counter is a cell of "Total" memory, in which all counted pulses are summed up and stored for a long period of time. Programmatically can be set various parameters defining the operation of the counter. The device has an energy-independent memory. The pulse counter is designed for installation in a dashboard (panel montage).

FEATURES

The CD6-3 digital pulse counter is a compact microprocessor device that serves to count electrical pulses. The number of pulses received at its input is visualized on a six-digit display. Except counting the impulses, its main function of the counter is to switch the electric circuit, in which it is turned on when a set value "N" is reached. The counter has a "Total" memory cell in which all counted pulses are accumulated and stored for a long period of time. The amount of accumulated pulses in the "Total" cell is displayed when the "Total" button is pressed. The pulse counter is widely used in automation of production, technological and other processes.

TECHNICAL PARAMETERS

Digital indication, LED - red 6 digits, h=10mm (height)
Counting range, N 1 … 999999 (pulses)
Inner divisor, d 1 … 9999
Supply voltage, Us 220 VAC ±10%
Power consumption, P 4 W (16 mA)
Output - Relay (NO+NC) 4A / 220VAC
Maximum counting frequency, Fmax 1 kHz (11 kHz option)
Operating temperature, Tamb -20º...+50º C
Degree of protection IP40
Joining Terminal block
Overall dimensions 95х49х113 mm

Programmable parameters

Limit value of pulses, N 1 ÷ 999999
Inner divisor,  d 1 ÷ 9999
Time between two adjacent pulses (00 = infinity),  t (sec) 0.0 ÷ 999.9
Active input front (high / low),  In Hi / Lo
Operating mode (increment / decrement) Inc / dEc
Interruption of the supply voltage,  Us :
      - after an interruption, the counting continues from the current data Cont
      - after an interruption, the counting automatically starts from the beginning Full
      - after an interruption, a stop mode of the current data is established Ucc
      - after an interruption, the counter is reset Goto
Automatic start when the power is turned on for the first time no / Auto
Initial state of the output relay (Status),  St ⌈‾⌉  /  ⌉_⌈

Schemes of connection

Scheme of connection of NPN sensor to CD6-3 and LMD6-5 counter

Fig.1

Connecting an NPN sensor to the counter input

Scheme of connection of a pushbutton to the CD6-3 and LMD6-5 counters

Fig.2

Connecting switch K1 to the counter input

PNP sensor connection diagram

Scheme of connection of PNP sensor to controller

Fig.3

Connect a PNP sensor to the counter input by adding a 2K / 0.5W resistor

Overall dimensions (mm)

Overall dimensions of the housing 95x49x113 of the controller for panel mounting

Short description

The CD6-3 digital pulse counter is an electronic device used as a means of automating production processes. Used for switching direct current and alternating current electrical circuits.

Typical parameters of pulse counter CD6-3

TYPE SUPPLY VOLTAGE CONSUMPTION
CD6-3 / 12-24V11÷31VDC / 11÷27VAC2W (85mA)
CD6-3 / 220V220VAC ±10%4W (16mA)