Digital pulse counter CD6-5R/12-24V
N=(1 - 999999), Us=12÷24V ac/dc, Output 4A/220V, 95x49x113mm
The CD6-5R/12-24V digital pulse counter is a microprocessor device with a 6-digit display. It counts up to 999999 and has one output relay. The counter is reversible and can sum and subtract pulses. It has two inputs "A" and "B", and operate together with an encoder or a sensor with two phase-shifted outputs type "NPN" (OVM1-18.24.F). Programmatically can be set various parameters defining the operation of the counter. The device has an energy-independent memory. The pulse counter is designed for installation in a dashboard (panel montage).
FEATURES
The CD6-5R digital pulse counter is a compact microprocessor device that serves to sum and subtract electrical impulses. It is designed to operate in combination with an encoder or a sensor with two phase-shifted outputs type "NPN". The counter visualizes only positive numbers. Except counting the impulses, its main function of the counter is to switch the electric circuit, in which it is turned on when a set value "N" is reached. The pulse counter is widely used in automation of production, technological and other processes.
TECHNICAL PARAMETERS
Digital indication, LED - red | 6 digits, h=10mm (height) |
Counting range, N | 1 … 999999 (pulses) |
Inner divisor, d | 1 … 9999 |
Supply voltage, Us | 12÷24V ac/dc (11÷31Vdc / 11÷27Vac) |
Power consumption, P | 2 W (85 mA) |
Output - Relay (NO+NC) | 4A / 220VAC |
Maximum counting frequency, Fmax | 11 kHz |
Operating temperature, Tamb | -20º...+50º C |
Degree of protection | IP40 |
Joining | Terminal block |
Overall dimensions | 95х49х113 mm |
Programmable parameters
Limit value of pulses, N | 1 ÷ 999999 |
Inner divisor, d | 1 ÷ 9999 |
Time between two adjacent pulses (00 = infinity), t (sec) | 0.0 ÷ 999.9 |
Active input front (high / low), In | Hi / Lo |
Interruption of the supply voltage, Us : | |
- after an interruption, the counting continues from the current data | Cont |
- after an interruption, the counting automatically starts from the beginning | Full |
- after an interruption, a stop mode of the current data is established | Ucc |
- after an interruption, the counter is reset | Goto |
Automatic start when the power is turned on for the first time | no / Auto |
Initial state of the output relay (Status), St | ⌈‾⌉ / ⌉_⌈ |
Upon reaching N: is reset / the output turns off, the counting continues | End G / End C |
Schemes of connection
Fig.1
Connecting an NPN encoder to the counter input
Fig.2
Connection of two NPN sensors to the input of the counter
PNP encoder connection diagram
Fig.3
Connect a PNP sensor to the counter input by adding two 2K / 0.5W resistors
Overall dimensions (mm)
Short description
The CD6-5R digital pulse counter is an electronic device used as a means of automating production processes. Used for switching direct current and alternating current electrical circuits.
Documentation
Typical parameters of pulse counter CD6-5R
TYPE | SUPPLY VOLTAGE | CONSUMPTION |
---|---|---|
CD6-5R / 12-24V | 11÷31VDC / 11÷27VAC | 2W (85mA) |
CD6-5R / 220V | 220VAC ±10% | 4W (16mA) |